Widget HTML Atas

Kitchenaid Microwave Door Switch Test

The microwave oven can store thousands of volts of electricity in its. The microwave runs with the door open.


Vintage Dixie Range Bottom Bake Element 21" X 17.75" X 3

Scott halseth, the switch is called door sensing switch, part number wb24x829.

Kitchenaid microwave door switch test. Kitchenaid superba microwave door switch. When your microwave door latches, the latch connects to a switch, which when it activates, allows the microwave to receive power. To avoid this, cancel and sign in to youtube on your computer.

A door switch is a simple on/off mechanism that prohibits the microwave from operating when the door is open. Microwave door switch test repair help you 11 89 ge microwave door switch szm v16 lg micro oven switches 2pcs set microwave oven door switch for lg ge starion szm v16 fd Due to the potential for electric shock, it is extremely dangerous to replace the.

This microwave door switch provides power to the various components in the microwave when the door is in a closed position, and interrupts power when the door is open. How do i fix my kitchenaid microwave? If this switch has gone faulty, it can cause the microwave not to run at all or it can cause it to stay active even when the door is.

Seal and sealing surfaces (arcing, wear and other damage) 4. If your microwave will not turn or heat properly, there could be an issue with the door switch. Videos you watch may be added to the tv's watch history and influence tv recommendations.

Interlock switches to remove the secondary interlock switch: Kitchenaid microwave shuts off after a few seconds. When you close your microwave door, the door switch is activated, meaning it provides power to some of the components in the appliance.

With the door open, place the multimeter leads on the connectors on the primary switch first. Once removed, use a multimeter to test the switch for continuity. If the door continues to run even when you open the door, then it is likely a door interlock switch fault.

Set the multimeter to ohms to test the three switches. When the door switch is closed, it instructs the other microwave components to supply power and to turn off the heating. Before you begin to test a door interlock switch, first make sure your microwave oven is unplugged, and that your capacitor is discharged.

Microwave keep ing fuses kitchenaid kbhc109jss05 microwave microwave door switch test kitchenaid superba microwave and oven i ve a kitchenaid superba microwave and kitchenaid superba oven microwave combo. If any of the switches is visibly damaged or. The interior lights should come on when the door is opened.

How to repair a kitchenaid microwave. Once you have diagnosed the problem we have the oem replacement door switch that fits your appliance. Removing the microwave door interlock switches and the cavity light warning cavity light primary & monitor sec.

If you don’t see any obvious signs of failure, use a multimeter to test each switch for continuity. Kitchenaid microwave shuts off after a few seconds door switch. Replaced the faulty switch and voila, the closed door issue got resolved.

To check the heating of the appliance, kitchenaid recommends placing a cup of water in the center of the microwave and setting the appliance on high for one minute. A defective door switch can restrict power, causing your microwave to cease functioning even when the door is. Additionally, the door switch is referred to as an interlock switch.

You can check the switch for. How to test the switches. The multimeter should be set to rx1.

A door switch might be failing intermittently. If playback doesn't begin shortly, try restarting your device. To determine if any of the door switches are defective, use a multimeter to test each of the switches for continuity.

Clean the turntable support if the turntable does not operate. A) remove the two mounting bracket electrical shock hazard screws from the front of the switch disconnect power before servicing. Inspect the cabinet and interior of the microwave for damage.

If you don’t see any obvious signs of failure, use a multimeter to test eac. When your microwave switches on but does not heat up, it may be a faulty door switch. To test the interior lights:

Before you begin to test a door interlock switch, first make sure your microwave oven is unplugged, and that your capacitor is discharged. When closing the door the multimeter should produce a beep if the switch is good. There may be more than one.

If the door switch is not shutting the light(s) off the refrigerator may get too warm Place the probes on the terminals, and first test the switch without the button pushed in. Because of this the microwave will not function.

High voltage capacitor, even after the microwave oven has been unplugged. If any of the door switches does not have continuity, replace it. Next, locate the door interlock switch and remove it from the microwave (you will probably have to remove the microwave’s cabinet to get access to it).

You could use a multimeter and see if you get. How to test if your refrigerator door switch works. The interlock monitor switch will immediately cause the oven fuse to blow if the door is opened and the primary door interlock switch and/or the secondary interlock switch contacts fail.

Microwave door switches are only an inch long. When the door switch is opened, it instructs the other microwave components to supply power and turn off the heating. On the other hand, when you open your microwave door, the door switch cuts off power to the microwave, which is why your appliance shuts down.

If the water is not warm, check the controls and make sure you are using the correct power level. Kitchenaid microwave ovens have a monitoring system designed to assure proper operation of the safety interlock systems. This door switch is approximately 1 1/2 inches long, and has 2 metal prongs called terminals that extend from its body.

Firmly press the start key. When the microwave door is closed the control panel says close door on the microwave when it is already closed! Check each of the door switches for signs of overheating, arcing, or burning.

A door switch might be failing intermittently. When the door is opened during a cook cycle, the monitor switch, door sensing switch, primary interlock switch and power relay are deactivated. Do not operate or allow the oven to be operated with the door open.

Make the following safety checks on all ovens to be serviced before activating the magnetron or other microwave source, and make repairs as necessary: After removing the left two panels, there was a third switch which tested at 005 when closed, while the good ones tested at 001 when closed. Remove the spacer attached to the inside of the microwave oven door and close the door.

Depress the door switch manually with the door open to verify the interior lights are turning off and on; Check each of the door switches for signs of overheating, arcing, or burning. Please note that the primary and secondary switches are tested with the door open.


This Dryer Roller is a direct replacement for Samsung part


Whirlpool/Kitchenaid/Maytag/Kenmore Range Oven Light


FRIGIDAIRE/ELECTROLUX/SEARS KENMORE RANGE/OVEN Bake


99+ Under Ice Maker Reviews Kitchen Design and


Details about VINTAGE AMERICAN MOTORS RANGE 120VAC


Ways to Fix Your Broken Appliances Stove repair, Cooking


31001556 Dryer Igniter for Whirlpool Whirlpool, Light


Whirlpool/KitchenAid/Sears Kenmore Dishwasher 3368827 Door